SOUPAPE-ANTI
Valves & Flow Regulation

Anti-surge valve

Valve protecting pipelines from destructive water hammer, tested at PN 10 and PN 16. Spring types A, B or C per adjustment range (1 to 17 bar) — max flow up to 68 L/s at DN 60.

Available references

1

Prices provided by quote — answer within 24 business hours.

Technical question? Message us on WhatsApp

SMEEPIA — DATA SHEET

Technical specifications

Tested at PN 10 and PN 16, these valves protect pipelines from destructive water hammer. The spring type (A, B, C) determines the adjustment range.

Adjustment ranges and performance

DNSpring typeAdjustment range (bar)Overpressure (bar)Max flow (L/s)
60A1 – 72,545
60B6 – 122,960
60C10 – 173,368
65A2 – 7—*—*
65B6 – 12—*—*

* Contact SMEEPIA for specific DN 65 overpressure and flow performance data.

Norms & standards

PN 10 / PN 16